BELT DRIVEN CENTRIFUGAL IN SOUNDPROOF CABINET WITH SANDWICH PANELS
MANUFACTURING FEATURES
• Impellers made of polyamide reinforced with fibreglass up to size 12/12 (33/33). Other models are made of galvanised steel sheet.
• , , range fans assembled in soundproof cabinets.
• Ventilation box with 30 mm aluminum profile structure, nylon corners, galvanized sandwich panels with internal insulation rockwool (25mm thickness) class A1 (non-combustible) of 90kg/m3 density. All panels are equipped with "fastening system" for the quick assembly and disassembly whenever required, either for cleaning, maintenance or exchanging of panels.
• Fan assembled on antivibration mountings.
• Supplied with motor, pulleys and belts.
• Connection gland included.
• Squirrel cage asynchronous standard motor, IP-55 protection and rated class F insulation. Standard voltages 230/400V 50Hz for three phase, motors up to 4kW and 400/690V 50Hz for higher powers.
APPLICATIONS
Designed for inline installation, indoor or outdoor assembly, they are suitable for:
• Air renewal in buildings and industries.
• Industrial and professional kitchen hood.
• Maximum working temperature: 60ºC.
UNDER REQUEST
• Special voltages
• 2 speed motors.
• LG0 position.
• Impeller made of galvanized sheet.
A | B | C | D | E | F | H | I | J | K | L |
---|---|---|---|---|---|---|---|---|---|---|
950 | 950 | 1220 | 483 | 139 | 328 | 556 | 197 | 890 | 890 | 41 |
MANUFACTURING FEATURES
• Metal insulators designed to work with compression with 85% insulation according to the following arrows (travel in mm) and rpm:
Arrow (mm.) r.p.m.
20 mm >600 r.p.m.
30 mm >500 r.p.m.
• Made of high quality elastic steel, with rectangular base and rubber mat to improve the grip. It treats of a resistant product and easy assembly, that avoids all type of vibrations of the fans to the structure of the premises.
• Operating temperature from -45 ° C to + 120 ° C.
APPLICATION
• To install under machines with rotating components, ventilation groups, fans, ventilation boxes, etc.
MANUFACTURING FEATURES
• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.
*Máx. thermal current air (A)
Weather protective roof made of galvanized steel for BOX BD PLUS, ZBBV PLUS, and ZBBV
MANUFACTURING FEATURES
• Outdoor flange with bird guard.
• Made of galvanized Steel.
• VIS OUT = Outlet
• VIS IN = Inlet
MANUFACTURING FEATURES
• Structure in aluminum profile 30mm, nylon corners, galvanized sandwich panels with internal insulation rockwool (25mm thickness) class A1 (non-combustible) of 90kg/m3 density
• All panels are equipped with "fastening system" for the quick assembly and disassembly whenever required, either for cleaning, maintenance or exchanging of panels.
• Box is supplied without filters.
(Check the filter units needed for the drawer surface, Box filter for need 2 filter of each granulometry)
Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.
• High filtration area, high efficiency, compact and economic filter.
• Media: Mini pleat fiberglass paper
• Frame: Galvanized steel
• Maximum T° in continuous service: 100°C
• Humidity: 100% RH
• Tested for food contact according to CE 1935/2004
• Certified for microbial development (ISO 846-VD 6022)
Filtration for air treatment units equipped with a pre-filter upstream, and air-conditioning units.
• High filtration area, high efficiency, compact and economic filter.
• Media: Mini pleat fiberglass paper
• Frame: Galvanized steel
• Maximum T° in continuous service: 100°C
• Humidity: 100% RH
• Tested for food contact according to CE 1935/2004
• Certified for microbial development (ISO 846-VD 6022)
Filter cells for rough primary filtration for air treatment units or air intake grids.
• Thick synthetic media with high retention capacity pleated between 2 rigid screens.
• Large filter surface.
• Frame: galvanised,
• Maximum continuous operating temperature: 70°C
• Relative humidity: 100%
• Tested for food contact according to EC 1935/2004